Search

Page 30 of 30 (300 items) « First ... < Previous 26 27 28 29 30
  • How do I assign fake numbers to an imported clip?

    I'm trying to assign some bogus timecode or ink numbers to an imported image sequence so that the optical list will offer some reference of where the shot starts and stops, but no number I put in the bin field for this clip will stick. How do I assign fake numbers to an imported clip? I can assign a camera roll, but that's not enough! Thanks.
    Posted to Film and 24p (Forum) by chuckkahn on Thu, Jun 22 2006
  • Re: Filmscribe printing wierdness

    Even when I print to landscape mode, every other page is blank. See these thumbnails of pages 1-45 in a print-to-pdf I just made. I usually end up having to copy and paste from Filmscribe to Notetab Light, search-and-replace the odd characters (those little square thingys that are at the beginning of every other line) and print that version. It would
    Posted to Film and 24p (Forum) by chuckkahn on Thu, Jun 22 2006
  • pull list comments for DI

    I thought it would be a good idea to include comments and/or locators if film scanning (for DI) was being performed using the pull list. Then, for example, if the fourth shot from camera roll A1 needed to be resized because of film damage on the right of frame, the resizing could be done at the scanning stage for maximum quality. I tried putting comments
    Posted to Film and 24p (Forum) by chuckkahn on Wed, Jun 21 2006
  • portserver and bin access

    Three times today, portserver access problems have happened under similar circumstances: 1) I open a bin in Filmscribe 2) I change the bin in Media Composer Adrenaline 3) I try to re-open the bin with changes in Filmscribe Step 3 is when unity access freezes up. Could bin access issues between Filmscribe & Adrenaline cause portserver to crash?
    Posted to Avid Unity / Workgroups / Local Storage (Forum) by chuckkahn on Tue, Jun 20 2006
  • comments in pull list

    I see that Filmscribe version 21.1 has checkboxes in pull and optical pull to include locators and comments, but the generated pull list does not have any comments from my sequence's locators or comments. Are comments really possible in pull lists?
    Posted to Film and 24p (Forum) by chuckkahn on Tue, Jun 20 2006
  • PAL field 2 dominant

    Can PAL field 2 dominace be reversed in the Symphony? Our frame sequence export shows field blending from adjacent frames because field 2 is dominant.
  • Re: Matrox Millenium G550 AGP driver?

    Oh sorry, this is an Xpress system in the case of the Matrox. The nVidia is an Adrenaline.
    Posted to Avid Media Composer - PC (Forum) by chuckkahn on Mon, Jun 5 2006
  • Matrox Millenium G550 AGP driver?

    I'm on another system that is using a Matrox Millenium G550 AGP, but the C:\Program Files\Avid\Utilities\ folder doesn't have a Matrox folder. It does have the nVidia folder with a 77.18_win2kxp_international_whql.exe file. It is currently installed with driver G550DHD 5.13.01.1320.
    Posted to Avid Media Composer - PC (Forum) by chuckkahn on Mon, Jun 5 2006
  • Where is "Ink Film"?

    I typed "Ink Film" into the bin heading and came up with an "Ink Film1" heading. Which would indicate that "Ink Film" is a reserved (and existing?) bin heading. If only I could access it...
    Posted to Film and 24p (Forum) by chuckkahn on Fri, May 26 2006
  • 3 perf corruption

    I created a test 3-perf project on MCA v1.3.1 and imported an ALE file into a bin and closed it. I then accessed the same project over our Unity with Xpress Pro HD 5.1. On opening the bin I received a prompt that said: "This bin contains 3 Perf information in an old format that is not supported in this release. Click OK to convert to the new format
    Posted to Film and 24p (Forum) by chuckkahn on Fri, May 26 2006
Page 30 of 30 (300 items) « First ... < Previous 26 27 28 29 30

© Copyright 2011 Avid Technology, Inc.  Terms of Use |  Privacy Policy |  Site Map |  Find a Reseller